Last updated:
Tuesday, 07 February 2012

Boiler Menu

Jet Spray Pressurized Deaerator

Download Brochure 

Features

  • jet-spray-lg.jpgUNIQUE JET SPRAY scrubber design deaerator guarantees removal of all dissolved oxygen in excess of .005 cc/liter (7 ppb).
  • ELECTRONIC INSTRUMENTATION FOR MODULATING DEAERATOR LEVEL control includes a HART compatible differential pressure transmitter, PID controller, and motorized control valve.
  • MULTIPLE DEAERATOR CONFIGURATIONS: vertical or horizontal vessels provide maximum flexibility using minimum footprint.
  • ONLY STAINLESS STEEL components come in contact with undeaerated water. Deaerator spray nozzle, scrubbing section and internal vent condenser are all stainless steel.
  • A.S.M.E. Code and National Board stamped receivers - 50 psi standard vessel options include stress relieving, non-destructive testing and full vacuum.
  • CUSTOM ENGINEERED PACKAGED DEAERATOR SYSTEM includes boiler feedwater pumps and quality components to insure reliable service.

Advantages

  • The Jet Spray deaerator provides excellent performance utilizing the high velocity incoming steam to atomize makeup water and pumped returns. Stainless steel internal components provide reliable performance for many years. This superior spray-type design directs the cleanest incoming steam to scrub out the last traces of oxygen from the cleanest water.
  • GUARANTEED DEAERATOR PERFORMANCE .005 cc/liter per ABMA testing procedures. Standard sizes ranging from 6,900 lbs/hr to 300,000 lbs/hr.
  • CUSTOM ENGINEERED PACKAGED DEAERATOR SYSTEM results in a small foot print, minimal onsite installation costs, and a single source of responsibility for all major components.

Operation

WATER FLOW- Incoming undeaerated water and pumped returns enter the deaerator through a spring-loaded stainless steel nozzle which directs the flow in conical sheets into the steam atmosphere of the direct contact vent condenser. At this point, the water temperature in the deaerator is raised to within a few degrees of steam temperature and most of the corrosive, non-condensable gases are removed. The water is directed by a stainless steel tray section into the Jet Spray atomizing valve. Here a high velocity of incoming pure steam atomizes the water into minute particles. This violent scrubbing action removes the last traces of dissolved gases. The hot, deaerated water then falls to the storage compartment for boiler use.
 

STEAM FLOW- Steam initially enters the deaerator through a special stainless steel Jet Spray atomizing valve. This valve is designed to fully atomize and provide complete deaeration under all load conditions. This design insures that the purest steam comes in contact with the purest water. Once this high velocity steam mechanically shakes out the last traces of non-condensable gases from the water, it flows upward into the preheated area where it meets the incoming makeup water and pumped returns. This water continually condenses the steam which preheats and releases the non-condensable gases into the internal vent condenser where they are metered harmlessly from the deaerator into the atmosphere. This action causes more steam to be drawn into the system to complete the cycle.

MODEL NUMBERRATED CAPACITYRECEIVER SIZE Tank Diameter x Overall LengthSYSTEM CAPACITY TO OVERFLOWAPPROXIMATE OVERALL DIMENSIONS, in.APPROXIMATE WEIGHT, lbs.
LBS/HRHPGALS.MINS.HT*LW**SHIPPINGOPERATINGFLOODED
1JS5
2JS5
3JS5
4JS5
6JS5
8JS5
3,450
6,900
10,350
13,800
20,700
27,600
100
200
300
400
600
800
36" x 5' 5"
36" x 5' 5"
48" x 5' 10"
48" x 5' 10"
48" x 7' 10"
54" x 9' 11"
155
155
285
285
413
697
21
11.1
13.9
10.3
10
12.6
92
92
102
102
102
108
65
65
65
65
94
119
48
48
60
60
60
66
1400
1400
2000
2000
24000
3100
2700
2700
4400
4400
5500
8400
3500
3500
6000
6000
7560
11800
10JS5
12JS5
15JS5
18JS5
21JS5
24JS5
34,500
41,400
51,750
62,100
72,450
82,800
1,000
1,200
1,500
1,800
2,100
2,400
54" x 9' 11"
60" x 10' 4"
60" x 12' 4"
60" x 14' 4"
66" x 14' 4"
66" x 16' 4"
697
866
1060
1254
1450
1658
10.1
10.4
10.3
10.1
10
10.1
108
112
112
112
112
118
119
124
148
172
172
196
66
72
72
72
78
78
3100
3600
3850
4100
4800
5300
8400
10800
12650
14500
16800
19200
11800
15000
17650
20300
24500
27900
30JS5
36JS5
45JS5
60JS5
75JS5
90JS5
100,000
125,000
150,000
200,000
250,000
300,000
3,000
3,600
4,500
6,000
7,500
9,000
72" x 16' 4"
72" x 18' 7"
84" x 16' 11"
84" x 18' 11"
96" x 19' 3"
96" x 23' 3"
2010
2518
2990
4000
5046
6170
10
10.1
10
10
10.1
10.3
124
124
136
136
148
148
199
223
203
227
231
279
84
84
96
96
108
108
6000
6550
8100
9000
10200
12100
22500
25200
32300
40600
52200
63600
29600
33100
41000
51400
66000
80500

 

Jet Spray Pressurized Deaerator - Components

  1. High Water Alarm Switch
  2. Make-up Nozzle
  3. Y-Strainer
  4. Pressure Control Valve
  5. Steam Nozzle
  6. Make-up Control Valve
  7. Level Controller
  8. Boiler Feed Pump Motor
  9. Boiler Feed Pump
  10. Make-up Ball Valve
  11. Make-up Globe Valve
  12. Pressure Gauge (0-15#) w/Cock
  1. Temperature Gauge w/Thermowell (50 DEGREE - 500 DEGREE F)
  2. Safety Relief Valve (Set at 50#)
  3. Sentinal Relief Valve (Set at 20#)
  4. Water Gauge Glass
  5. Overflow Trap
  6. Low Water Alarm & Cut Off Switch
  7. Recirculation Orifice Union
  8. Recirculation Ball Valve
  9. Suction Coupling
  10. Suction Gate Valve
  11. Drain Ball Valve
  1. Vent Gate Valve
  2. Level Transmitter
  3. Make-up Y-Strainer
  4. Recirculation Check Valve
  5. Starter
  6. Control Panel (NEMA 1)
  7. Water Column Drain Ball Valve
  8. Water Column Isolation Ball Valve
  9. Chemical Feed Quill
  10. Discharge Pressure Gauge (0-400#)
  11. Discharge Ball Valve
  12. Discharge Check Valve