Monday, 06 September 2010
LCD Dominator Series
The LCD Dominator™ Series from RBI offers a competitively priced indoor/outdoor unit that meets the low NOx requirement, while maintaining superior performance and serviceability. The LCD provides dependable performance in rugged environments and process applications, with a wide 225 - 2300 MBH range. At the heart of the unit is a sealed combustion chamber that provides the flexibility of using outside air or mechanical room air for combustion. Priced in line with the atmospheric category heaters, the LCD features smaller vent sizes, resulting in a lower total installation cost.

Brochure

Installation Manual

Warranty

 

Standard Equipment:
82% Efficiency
Bronze Headers (Water Heaters)
Cast Iron Headers (Boilers)
Integral PID Staging Control
Low NOx
Slide Out Heat Exchanger
Finned Copper Tube Heat Exchanger
ASME Pressure Relief Valve Mounted
Pump Delay Control
Indicator LIght Panel
Uginox Alloy Stainless Steel Burners
On/Off Firing
2 Stage Firing (600 - 2300)
Sealed Combustion Chamber
Temperature/Pressure Gauge
Thermometer
Flow Switch Mounted and Wired
FM Compliant Gas Train
Category I or III Venting
20 Amp Pump Contactor Single Phase
Leak Test Valves
Side Combustion Air Intake (225 - 2300)
Rear Combustion Air Intake (750 - 2300)
Direct Vent up to 35’ Equivalent
SCAQMD Rule 1146.2
Ventura County APCD Rule 74.11.1
CSA Designed Certified and Listed
National Board Certified

 

 

Specifications:

Water Heater Written Specification

Heating Boiler Written Specification 

Options:
Propane Gas
Cupronickel Heat Exchanger
Wired & Mounted Flange
5’ Pump Pigtail
Alarm Bell
Flame Failure Dry Contact
Enable/Disable Relay 24V
Low Gas Pressure Switch
High Gas Pressure Switch
Right Hand Water Connection
C.A.D. Dry Contact
Freeze Protection Kit
Stainless Steel Jacket
Power Venting Wiring
Three Phase Pump Contactor
Sidewall Vent Kit
Sidewall Vent Kit w/ Air Intake Hood
Vent Termination Hood
Air Intake Hood
Barometric Damper
Outdoor Installation
Pump
Rack Kit

Piping Diagrams:

Variable Low Temperature Thermostatic Mixing Valve

Two Heaters / Two Vertical Tanks

Single Boiler / Primary/Secondary / Low Temperature

Single Boiler / Primary/Secondary

One Heater / One Vertical Tank

Multiple Boilers / Primary/Secondary

 

Submittals:

Submittal Data Cover Sheet

750 Plan View Drawing

600 Plan View Drawing

400 Plan View Drawing

300 Plan View Drawing

2300 Plan View Drawing

225 Plan View Drawing

1970 Plan View Drawing

1650 Plan View Drawing

1480 Plan View Drawing

1200 Plan View Drawing

1050 Plan View Drawing

GOES Heating Systems is proud to offer a wide variety of commercial boilers and water heaters in Southwest Texas.  We have locations in Houston, Austin, and San Antonio.